connecting_cup_dispensing_unit [2025/12/17 15:10] – [Connecting dispensing unit No. 2] ishakeradminconnecting_cup_dispensing_unit [2025/12/17 15:20] (current) ishakeradmin
Line 26: Line 26:
 To activate the module programmatically, enable and save the {{ :cup-dispencer-option-usa.png?linkonly |"Cup dispencer module"}} option.  To activate the module programmatically, enable and save the {{ :cup-dispencer-option-usa.png?linkonly |"Cup dispencer module"}} option. 
  
-Check the operation of the dispensing unit (without loaded cups) using the {{ :cupdispencertest_button.png?linkonly |"Cup test"}} button.+Check the operation of the dispensing unit (without loaded cups) using the {{ :cup-test-button-usa.png?linkonly |"Cup test"}} button.
  
 ---- ----
Line 44: Line 44:
 **Attention!** Before commissioning, the unit must be calibrated for the cups used! **Attention!** Before commissioning, the unit must be calibrated for the cups used!
  
-To activate the module programmatically, enable and save the {{ :cup-dispencer-option-usa.png?linkonly |"Cup dispencer module"}} option. Test the dispensing unit (without cups loaded) using the {{ :cupdispencertest_button.png?linkonly |"Cup Test"}} button.+To activate the module programmatically, enable and save the {{ :cup-dispencer-option-usa.png?linkonly |"Cup dispencer module"}} option. Test the dispensing unit (without cups loaded) using the {{ :cup-test-button-usa.png?linkonly |"Cup test"}} button.
  
 ---- ----
Line 66: Line 66:
 ===== Problems? ===== ===== Problems? =====
  
- 
-In some cases, the problem with dispensing the cup remains even after calibration; the cup may get stuck during dispensing and not fall into the catcher: 
-{{ :ролики_выдача_т.jpg?nolink&300 |}} 
- 
-{{ :проблема_с_выдачей_1.jpg?nolink&300 |}} 
- 
-Push the cups out of the tube and inspect the guide rollers - they should all be facing the same direction: 
- 
-{{ :отщепитель_ролики.png?nolink&600 |}} 
- 
----- 
 If the cup is not dispensed (the dispensing unit does not turn on or the motor does not complete its rotation), check the order of the terminal connections to the motor and the dispensing unit, and the controller board. If the cup is not dispensed (the dispensing unit does not turn on or the motor does not complete its rotation), check the order of the terminal connections to the motor and the dispensing unit, and the controller board.
  