User Tools

Site Tools


error_1_no_water_touch2

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
error_1_no_water_touch2 [2025/11/25 14:09] – created ishakeradminerror_1_no_water_touch2 [2025/11/25 14:15] (current) – [Adjusting the water level when connecting to the water supply] ishakeradmin
Line 9: Line 9:
  
  
-To reset the error, press {{ :t2-controller_reboot.png?linkonly |CONTROLLER REBOOT}} button. If the error persists, start the {{ :t-waterpumping.jpg?linkonly |pumping water}} process in the service menu. Once the bleeding process is complete, press {{ :t2-controller_reboot.png?linkonly |CONTROLLER REBOOT}}.+To reset the error, press {{ :t2-controller_reboot.png?linkonly |CONTROLLER REBOOT}} button. If the error persists, start the {{ :t2-pumpingwaterbutton.png?linkonly |pumping water}} process in the service menu. Once the bleeding process is complete, press {{ :t2-controller_reboot.png?linkonly |CONTROLLER REBOOT}}.
  
 If the error reappears after rebooting, run diagnostics: If the error reappears after rebooting, run diagnostics:
Line 44: Line 44:
 {{ :воронка_миксера_уровень_воды.jpg?nolink&400 |}} {{ :воронка_миксера_уровень_воды.jpg?nolink&400 |}}
  
- - Adjust the water flow if necessary. Adjustment is made by turning {{ :t2-pipeline-ajusting.png?linkonly |регулятора давления}} with a "+" screwdriver;+ - Adjust the water flow if necessary. Adjustment is made by turning {{ :t2-pipeline-ajusting.png?linkonly |pressure regulator}} with a "+" screwdriver;
   - To increase the water flow, turn the regulator clockwise; to decrease it, turn it counterclockwise. Check the water level in the funnel.   - To increase the water flow, turn the regulator clockwise; to decrease it, turn it counterclockwise. Check the water level in the funnel.
   - Open the service menu and rinse the mixers by pressing buttons 1-4 on the screen one by one.   - Open the service menu and rinse the mixers by pressing buttons 1-4 on the screen one by one.
-  - Press {{ :t-controller_reboot.jpg?linkonly |CONTROLLER REBOOT}}. After the machine restarts, make sure that the No Water error 1 is no longer displayed on the screen.+  - Press {{ :t2-controller_reboot.png?linkonly |CONTROLLER REBOOT}}. After the machine restarts, make sure that the No Water error 1 is no longer displayed on the screen.
   - After setting the water level, check the water calibration in the service menu.   - After setting the water level, check the water calibration in the service menu.
  
Line 56: Line 56:
  
  
-**Answer:** {{ :t2-cooleronoff.png?linkonly |Turn off the machine's cooler}} for 30 minutes, then {{ :t-waterpumping.jpg?linkonly |pump the water}}. Without water, the cooler freezes and shuts off the water supply.+**Answer:** {{ :t2-cooleronoff.png?linkonly |Turn off the machine's cooler}} for 30 minutes, then {{ :t2-pumpingwaterbutton.png?linkonly |pumping water}}. Without water, the cooler freezes and shuts off the water supply.
  
 ---- ----
error_1_no_water_touch2.1764068993.txt.gz · Last modified: 2025/11/25 14:09 by ishakeradmin